Mitsubishi Electric MELSEC-F Series User Manual page 45

Hide thumbs Also See for MELSEC-F Series:
Table of Contents

Advertisement

FX
-1PG User's Manual
3U
Cancelling the remaining distance operation
The following operation cancels the remaining distance operation. When the remaining distance operation is
cancelled, the positioning completion flag remains off.
• When the start command of a different operation command is turned on during remaining distance
operation waiting, the remaining distance operation is cancelled, and the command input later starts the
operation.
In addition, even in the same operation command, when an operation is started by switching the address
specification method (relative/absolute), the remaining distance operation is cancelled, and the operation
starts with the newly set address specification method.
• When a write operation is executed to a buffer memory other than BFM#25 during the remaining distance
operation waiting, the remaining distance operation is cancelled, and the operation ends.
Operation during cancellation of the remaining distance operation
1-speed positioning
operation start
(BFM#25 b8)
STOP command
(BFM#25 b1)
READY
(BFM#28 b0)
Remaining distance
operation waiting
(BFM#28 b12)
Positioning
completion flag
(BFM#28 b8)
Speed
Operation speed I
Bias speed
ON
OFF
OFF
ON
OFF
OFF
ON
Write to BFM other than BFM#25
ON
ON
ON
OFF
OFF
6 Before Starting Positioning Operation
6.5 Handling the STOP Command
Time
1
2
3
4
5
6
7
8
9
10
39