3U
Variable speed operation
Change point
The
Operation when the operation
pulses.
speed I starts at a speed
The READY flag (BFM#28 b0) turns
lower than the bias speed
OFF.
Operation when the operation
The FX
speed I is changed to a
The READY flag (BFM #28 b0)
speed lower than the bias
remains OFF.
speed
The motor restarts the operation when
the STOP signal is set to OFF.
Operation when the STOP is
set from ON to OFF while the
operation command remains
ON
Variable speed
(BFM#25 b12)
STOP (BFM#25 b1
or STOP termi n al )
FX
-1PG
3U
FX
-1PG
does
not
output
3U
3U
-1PG stops the pulse output.
Speed
Operation
speed I
Time
ON
operation
OFF
ON
Appendix C: Differences with FX2N-1PG
FX
-1PG
2N
The motor operates at the bias speed.
(The motor operates at 10 Hz if the
bias speed is set to "0".)
The motor operates at the bias speed.
(The motor operates at 10 Hz if the
bias speed is set to "0".)
The motor does not restart the
operation even if the STOP signal is
set to OFF.
Speed
Operation
speed I
Time
Variable speed
ON
operation
(BFM#25 b12)
STOP
OFF
ON
(BFM#25 b1)
Appendix C-3 Differences in Operation
Replacement point
Change the sequence program so
that the operation speed I at the
beginning is set to the bias speed.
Change the sequence program so
that the operation speed I is changed
to the bias speed.
Confirm that no problem is expected
in the system when the operation is
restarted by setting the STOP signal
to OFF.
Change the sequence program as
needed so that the motor is stopped
by the STOP signal, the operation
command is set to OFF, and then the
STOP signal is set to OFF.
11
A
B
C
135