-1PG User's Manual
3U

10.1.3 Buffer memory assignments

BFM No.
#0
Pulse rate
#2, #1
Feed rate
#3 b1, b0
#3 b3, b2
#3 b5, b4
#3 b6
#3 b7
Operation
#3 b8
parameter
#3 b9
#3 b10
#3 b11
#3 b12
#3 b13
#3 b14
#3 b15
#5, #4
Maximum speed
#6
Bias speed
#8, #7
JOG speed
#10, #9
Zero return speed (high speed)
#11
Zero return speed (creep)
#12
Number of zero-point signal for zero return
#14, #13
Zero-point address
#15
Acceleration/deceleration time
#16
Starting delay time
#18, #17
Target address Ι
#20, #19
Operation speed Ι
#25
Operation command
#28
Status information
#32
Positioning parameter selection
Name
System of units
Interrupt input setting
Position data multiplier
Acceleration/deceleration
mode
Variable
speed
operation
acceleration/deceleration
setting
Pulse output format
Rotation direction
Zero return direction
Limit deceleration mode
DOG input polarity
Count start point
STOP input polarity
STOP input mode
Setting value
K8,192
PLS/REV
K1,000
μm/REV
b1=1, b0=0: Combined system
b3=0, b2=0: Not used
3
b5=1, b4=1:10
b6=0: Trapezoidal acceleration/deceleration
b7=0: Not used
H2032
b8=0: Forward pulse/Reverse pulse
b9=0: Current address increases
b10=0: Current address decreases
b11=0: Immediately stop
b12=0: NO contacts
b13=1: DOG backward end
b14=0: NO contacts
b15=0: Remaining distance operation
K200,000
K0
K10,000
K10,000
K1,500
K3
K0
K100
K0
K1,000
K200,000
M15 to M0
Refer to Subsection 10.1.2.
M35 to M20
Refer to Subsection 10.1.2.
K0
Use the positioning parameter
10 Program Example
10.1 Assignments
Remarks
10