Mitsubishi Electric MELSEC-F Series User Manual page 84

Hide thumbs Also See for MELSEC-F Series:
Table of Contents

Advertisement

FX
-1PG User's Manual
3U
BFM No.
High order
Low order
16bit
16bit
-
Point
• READY (b0) turns off while the error is active, and the start command is not received.
• When K0 is written to the status information, only the zero return execution completion (b2) turns off.
78
Bit
Item
No.
b5
PG0 input ON
Current value
b6
overflow
b7
Error flag
Positioning
b8
completion flag
#28
1-speed completion
b9
flag
Interrupt input 0
b10
ON
Interrupt input 1
b11
ON
Remaining distance
b12
operation waiting
b13
to
Not used
b15
Description
ON: PG0 input ON
OFF: PG0 input OFF
Same as the ON/OFF condition of the FX
terminal.
When the current address (BFM#27, #26 or BFM#59, #58)
value exceeds the ±32 bit data range, it turns on.
Turns off when the power is turned off, or when the DOG
type mechanical zero return operation or the data-set type
mechanical zero return operation is executed.
Turns on when an error occurs, and the error code number
is stored to the error code (BFM#29).
Turns off when the power is turned off or when error reset
(BFM25 b0) is executed.
Turns on when the positioning operation is completed
normally.
Turns off when the mechanical zero return operation start,
positioning operation start (excluding the variable speed
operation), or the error reset (only when an error occurred)
is executed.
Turns on when the 2-speed positioning operation, the
external command positioning, or the 1-speed of the
interrupt 2-speed positioning operation completes.
Conditions to turn on
-
When the 2-speed positioning operation, the external
command positioning operation, or the 1-speed of the
interrupt 2-speed positioning operation completes.
Conditions to turn off
-
At the completion of positioning
-
At the time of error occurrence
-
When the remaining distance operation is cancelled
-
When the remaining distance operation is not
executed (BFM#3 b15 or #37 b15 is ON), and when
the operation is decelerated and stopped by the
STOP command
ON: Turns on when the interrupt input 0 is detected in an
operation mode for which the interrupt input 0 is effective.
OFF: Turns off when the next operation is started.
ON: Turns on when the interrupt input 1 is detected in an
operation mode for which the interrupt input 1 is effective.
OFF: Turns off when the next operation is started.
Turns on during the remaining distance waiting when the
positioning operation (1-speed positioning operation, 2-
speed positioning operation, and interrupt stop operation)
decelerates and stops by the STOP input.
Turns off when the writing operation is executed to the
restart command or BFM other than BFM#25.
-
7 Buffer Memory
7.5 Monitor Data
R/W
Default
-1PG PG0
3U
R
-