Binding The New Switch To The Stack - Lenovo CN4093 Application Manual

10gb converged scalable switch
Hide thumbs Also See for CN4093:
Table of Contents

Advertisement

Binding the New Switch to the Stack

1. Log in to the stack interface.
2. From the stack interface, assign the csnum for the new switch.
230
CN4093 Application Guide for N/OS 8.3
Note: If replacing the Master switch, be sure to log in to the stack interface (hosted
temporarily on the Backup switch) rather than logging in directly to the newly
installed Master.
You can bind Member switches to a stack csnum using either the new switch's
asnum or MAC address:
CN 4093(config)# stack switch-number <csnum> universal-unic-id <uuid> bay
<Slot ID>
-or-
CN 4093(config)# stack switch-number <csnum> bind <asnum>
-or-
CN 4093(config)# stack bind
Note: If replacing the Master switch, the Master will not assume control from the
Backup unless the Backup is rebooted or fails.