4.13.3.4. Program report configuration
The Report section allows you to configure archived vari-
ables such as DataLog and Batch Report.
Report (Page 1) allows you to configure the DataLog by
determining the information to be stored.
The available parameters are:
•
Sampling time: determines the sampling frequency.
The time interval between one sampling and the next
can vary from 1 to 3600 seconds.
•
Include recipes: includes the program recipe at the
top of the DataLog.
•
File name job no.: includes the production batch num-
ber in the file name.
•
Encrypted file: apply encryption to the DataLog file.
The file can be decrypted with the DataLog Utility
application.
•
Comma : dot format: use the dot as the separation
between the integer and the decimal part of the num-
bers.
•
Sampled variables - Group: allows you to select the
variables to be sampled and assign them to a group,
so that they can be viewed in the DataLog Utility appli-
cation.
Assign the same group to homogeneous variables.
Touch the variable field to open a window pop-up to
select the variable. For details on the pop-up window,
see the description on page 103, while to find out
about management of saving on different media
•
on page 47
Report (page 2) allows you to include segments from digital
variables in the event report and to associate a descriptive
text for each event. In the report, events are listed after
sampling. The available parameters are:
•
Variable: lets you select digital variables.
Touch the variable field to open a window pop-up to
select the variable.
80703B_MHW_2850T/3850T_02-2019_ENG
For details on the pop-up window, see the description
on page 103.
•
String: lets you select a stored text string.
For details on the pop-up window, see the description
on page 103.
4.13.4. Read from disk sub-menu
In order to use this submenu you should be level 1 or 0,
depending on the instrument configuration. The visibility of
the reading button may be conditioned by parameters in
page x850 SETUP\CFG 2.
Opens a pop-up window that lists all programs stored on
the disk. For details on the pop-up window, see the de-
scription on page 103.
4.13.5. New prog sub-menu
In order to use this submenu you should be level 1 or 0,
depending on the instrument configuration.
The available parameters are:
•
Program name: touch the field to open the virtual
keyboard to enter the program name. The name can be
up to 16 characters long and must be unique.
•
Number: the program ID number. It is automatically
generated by the system and can not be modified.
•
Enable double step: the double step is a segment
composed of a ramp and a retention; if double step is
disabled, each ramp and each retention will constitute
a single segment created independently.
Double step
example
7
Single step
Step
example
1
7
The Save button appears when a name is attributed to a
program and is used to create the new program. Saving the
program opens page 1 in the program configuration Base
section. To continue see instructions on page 105 and
subsequent.
The Cancel button closes the window without saving the
changes made.
4. CONFIGURATION
Step 1: ramp 2 s +
hold 2 s
Step 2: ramp 2 s +
Step
Step
hold 0 s
1
2
9
11
12
Step 1: ramp 2 s
Step 2: hold 2 s
Step
Step
Step 3: ramp 2 s
2
3
9
11
12
s
s
69