13.1.6. Alarms

Type
Group
Boolean System ALARM_PRESENT
Boolean System NEW_ALARM
Boolean System PROBE_FAULT_n
Alarm
System NO_SD_CARD
Alarm
System DISK_FULL_NO_REC
Alarm
System IO_CABLE_FAULT
Alarm
System SIMULATOR_ON
Alarm
System DO_CC_M_N
Alarm
System FMIXn_AO_CC
Alarm
System FMIXn_AO_OP
Alarm
System IO_GUARD_TIME
Alarm
System IO_COMM_ERROR
Alarm
System IO_WRONG_CARD_n
Alarm
System IO_WRONG_STATE
Alarm
System PID_n_RANGE_OUT

13.1.5. Weekly clock

Type
Group
Boolean System ALARM_CLKn_CMDm
Boolean System ALARM_CLKn_SET

13.1.4. Energy

Type
Group
Ret
Boolean
ENERGY_RESET
System
Ret
Boolean
ENERGY_ENABLE
System
Ret
Register
ENERGY_TOTAL
System
Ret
Register
DO_n_TON
System
Ret
Register
DO_n_KWH
System
Ret
Register
PIDH_n_KWH
System
Register System
PIDC_n_KWH
80703B_MHW_2850T/3850T_02-2019_ENG
Variable name
Variable name
Variable name
Interval
Use
R
At least one alarm triggered.
R
No alarm triggered.
Probe n fault.
R
n can take on values from 1 to 16.
SD card configured, but not present. Recording not
R
active.
R
Disc full, no new records will be made
R
CANopen communication error
R
Simulator active
Digital outputs in short circuit. The card number (1-
R
4) and output number (1-8) are indicated
Analogue outputs in short circuit or overloaded. The
R
number of the FMIX card involved is specified
Analogue outputs without load or with non-stan-
dard load. Typically indicates that wiring has been
R
hooked up on a given output. The number of the
FMIX card involved is specified
R
CANopen error
R
CANopen communication error
R
Error in a specific card
Generic card error; may, for example, indicate a
R
card change.
A number of PID variables have gone off the scale
R
(+32767, -32768 without considering decimal
points). Control not possible
Interval
Use
Clock n command m.
R
n can take on values from 1 to 4.
m can take values 1 or 2.
Enable clock n (true = enabled).
R
n can take on values from 1 to 4.
Interval
Use
R W Reset energy count.
R W Enable energy counter command.
R
Total energy counter
Timer for ON status for digital output n.
R
n can take on values from 1 to 48.
kWh distributed by digital output n.
R
n can take on values from 1 to 48.
Total kWh for HEAT action of the PID controller.
R
n can take on values from 1 to 16.
Total kWh for COOL action of the PID controller.
R
n can take on values from 1 to 16.