They are split up into free, reserved and TDE MACNO reserved connections, and are changed in the
same way as the parameters.
The internal representation base is always as whole number

1.3 INPUT LOGIC FUNCTIONS (I)

The input logic functions are 32 commands that come from configured terminal board logic inputs,
from the serial line, and from the fieldbus. The meaning of this logical functions depend on the
application, so please refer to specific documentation.

1.4 INTERNAL VALUES (D)

Internal values are 128 variables within the drive that can be shown on the display or via serial on the
supervisor. They are also available from the fieldbus.
The first 64 values are referred to motor control part and are always present. The second 64 values
are application specific.
Pay close attention to the internal representation base of these values as it is important if readings
are made via serial line or fieldbus.

1.5 OUTPUT LOGIC FUNCTIONS (O)

The logic functions are 64, the first 32 display drive status and second 32 are application specific.
All output functions can be assigned to one of the 4 logic outputs.
6