The Startup time is the time necessary for motor and load to reach the maximum speed (set in P65)
with the nominal motor torque. This data has to be set in milliseconds in parameter P169.
It's useful to set some milliseconds of filter (P168) on order to avoid too much noise on torque
reference for the time derivative.
When it's enabled this function the torque reference produced is added to the speed regulator output.
The torque feed-forward can be very useful in the servo-drive application when the target is to follow
very promptly the speed reference, because it increases the bandwidth without using high gains on
speed regulator.
Note1: torque feed-forward isn't appropriate in load variable inertia applications.

2.2.3 TORQUE AND CURRENT LIMITS

Name
PRC_DRV_I_PEAK
PRC_MOT_T_MAX
PRC_DRV_CW_T_MAX
PRC_DRV_CCW_T_MAX
PRC_DRV_T_MAX
PRC_DRV_I_T_MAX
PRC_DRV_I_MAX
2.2.3.1
CHOOSING THE ACTIVE TORQUE LIMIT
The positive and negative torque limits are chosen to restrict the following values:
o P42 / P43 = maximum torque, in both directions according to rated torque;
o Maximum torque linked to maximum motor torque according to the rated torque
(parameter P41);
o Maximum torque set by the current limit;
o Maximum torque limit reference value generated by the application: sysMaxTorque
(symmetrical), sysMaxPositiveTorque and sysMaxNegativeTorque (asymmetrical)
o Maximum torque limited by the regulator output in order to back up the bus voltage
should the mains fail;
o Maximum torque controlled in the startup phase with the motor magnetized;
o Maximum torque limited in the controlled braking phase (as long as this function is
enabled by setting C47=1).
User's manual
Description
P40 - Current limit
P41 - Maximum torque at full
load
P42 - Maximum torque in the
positive direction of rotation
P43 - Maximum torque in the
negative direction of rotation
D30 - Maximum torque
D31 - Maximum torque by
current limit
D29 - Current limit
Min
Max
Default
0.0
200.0
200
0.0
400.0
400.0
0.0
400.0
400.0
-400.0
-0.0
-400.0
-100
100
0
-100
100
0
-100
100
0
Scal
UM
e
% DRV_I_NOM
40.96
% MOT_T_NOM
40.95
% MON_T_NOM
40.96
% MOM_T_NOM
40.96
% MOT_T_NOM
40.96
% MOT_T_NOM
40.96
% DRV_I_NOM
40.96