Frequency Speed Reference - TDE MACNO MINIOPD EXP User Manual

Table of Contents

Advertisement

H = active
x = does not matter
The digital potentiometer reference requires, to be enabled, activation of function I06 after allocating
an input or activating connection P218 (P218=1) .
In the parameters P215 and P216 the maximum and the minimum admitted reference values can be
marked for the digital potentiometer reference.

3.1.3 FREQUENCY SPEED REFERENCE

Name
REF_FRQ_IN
FRQ_REF_SEL
EN_FRQ_REF
FRQ_IN_SEL
FRQ_IN_PPR_SEL
TF_TIME_DEC_FRQ
PRC_APP_FRQ_SPD_REF
PRC_SPD_REF_TIME_DEC
KP_TIME_DEC_FRQ
MAXV_VF
FRQ_IN_NUM
KP_NEG_VF
KP_POS_VF
FRQ_IN_DEN
OFFSET_VF
User's manual
L = not active
Description
D12 - Frequency in input
P224 - Frequency speed
reference selection
P223 - Enable frequency
speed reference value
C09 - Frequency input setting
P220 - Encoder pulses per
revolution
P225 - Filter time constant of
frequency input decoded in
time
D14 - Frequency speed
reference value (application
generated)
D77 - Time Decode
Frequency input Speed
reference
P226 - Corrective factor for
frequency input decoded in
time
P88 - High precision analog
speed reference value:
Voltage matches max. speed
P221 - NUM - Frequency input
slip ratio
P159 - High precision analog
speed reference value:VCO
setting for negative voltage
reference values
P150 - High precision analog
speed reference value:VCO
setting for positive voltage
reference values
P222 - DEN - Frequency input
slip ratio
P10 - Offset for high precision
analog reference value
L -> H = From Off-line to On-line
Min
Max
Default
0
0
2
0
0
1
0
0
3
1
0
9
5
0.0
20.0
1.6
-100
100
0
-100
100
0
0.0
200.0
100
2500
10000
10000
-16383
16383
100
-16383
16383
4096
-16383
16383
4096
0
16383
100
-19999
19999
0
UM
Scale
KHz
16
1
1
1
1
ms
10
% MOT_SPD_MAX
163.84
% MOT_SPD_MAX
163.84
163.84
mVolt
1
1
1
1
1
1/100 mV
1
55