1 INTRODUCTION

To help the customer during the configuration of the drive, the manual is organized to follow faithfully
the structure of the configurator (OPDExplorer) that allows, according to a logical sequence, to set all
the sizes needed for the proper functioning of the drive.
In particular, each chapter refers to a specific folder of OPDExplorer which includes all the relative
parameters.
Also, at the beginning of each chapter of the manual, is showed the location of the folder in the
OPDExplorer tree, which the chapter refer, and the complete table of sizes of the folder in question.
The control values are divided as follows:
Parameters
Connections
Input logic functions
Internal values
Output logic functions
In the tables of the control value, the last column on the right "Scale" shows the internal
representation base of the parameters. This value is important if the parameters have to be read or
written with a serial line or fieldbus and represent the factor which to divide the value stored to
obtain the real value set, as following indicated:
Examples:
MAIN_SUPPLY
P87 – Main supply voltage
Value = 400
Scale = 10
Int. rep. = 4000

1.1 PARAMETERS (P)

The parameters are drive configuration values that are displayed as a number within a set range. The
parameters are mostly displayed as percentages, which is especially useful if the motor or drive size
have to be changed in that only the reference values (P61÷P65) have to be modified and the rest
changes automatically. The parameters are split up into free, reserved and TDE MACNO reserved
parameters.
The following rules apply:
Free parameters (black text in OPDExplorer): may be changed without having to open any key, even
when running;
Reserved parameters (blu text in OPDExplorer): may be changed only at a standstill after having
opened the reserved parameter key in P60 or the TDE MACNO reserved parameters key in P99;
TDE MACNO reserved parameters (violet text in OPDExplorer): may be changed only at a
standstill after having opened the TDE MACNO reserved parameters key in P99. While the key for
these parameters is closed, they will not be shown on the display.
Take careful note of the reference values for each parameter so that they are set

1.2 CONNECTIONS (C)

The connections are drive configuration values that are displayed as a whole number in the same
way as a digital selector.
User's manual
correctly.
5