In each group the dimensions are orderly in progressive order and they are
visualized only that indie use.

7.2.1 PARAMETERS (PAR)

They are definite parameters of dimension of setting whose numerical value
has an absolute meaning (for example: P63 = nominal frequency motor =
50 Hz) or they are of proportional value to the limit range (for example: P61
= motor nominal current = 100 % of the drive nominal current). They are
distinguished in free parameters, some modifiable always (Online), other
only to converter not in run (offline), reserved, modifiable only offline and
after access code to the reserved parameters (P60), or reserved for the
TDE MACNO, visible after having written the access code TDE MACNO
parameters (P99) and modifiable only offline. The characteristics of each
parameter are recognizable from the code of identification as under:
FIG. 2 (Parameters PAR)
For example: P60 r = parameter 60: reserved
1P00 t = parameter 100 TDE MACNO reserved
102