10 Drive Optimization with Start-Up Tool
10.8 Trace function (SW 4.2 and higher)
10.8.5

Display function

Softkeys
X marker
Y marker
Softkey
Expand
Softkey
Scale...
10-228
After measurement, you can display the result in graphical form.
By pressing horizontal softkey Display Fig. 10-11 is displayed.
The measured traces are displayed as a diagram.
Graph1 shows trace 1 and trace 2, graph2 shows trace 3 and
trace 4.
Fig. 10-11 Display of Graph1 and Graph2
The X/Y marker is switched on or off in the active graph. The corresponding
position value is displayed in the graph. You can move the markers with the
cursor keys.
Extension function for the X coordinate. The X marker must be activated.
The first time you operate the softkey Expand, a second X marker is displayed.
The first X marker remains fixed at the current position. The second marker can
be moved using the cursor keys.
If you press the softkey Expand again, the range between the markers is ex-
panded. In that way, you can expand the section.
After selection of this softkey, Fig. 10-12, Y axis scaling, appears on the screen.
You can scale the relevant traces in this display.
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
 Siemens AG 2000 All Rights Reserved
05.98
03.96