Siemens SINUMERIK FM-NC Installation And Startup Manual page 49

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

03.96
3.3
Connection of a 2nd MCP/customer OPI and/or 1 HHU (up to SW 3.1)
Enter areas for
You can now make the entries for the HHU in table 1.
transmitting and
1. Start in column as314//CPU1:: by selecting the first field.
receiving
2. Enter data area for reception or transmission from Fig. 3-6.
3. Declare the transmit and receive areas to be such. The transmit area is then
4. Table 1 with all its entries then looks like this:
GD identifiers
GD
GD
Note
The order in which inputs are made (transmit, receive) affects the way in which
GD identifiers are assigned and should be carefully observed as shown by the
above example.
Compilation
You now need to select compilation.
The GD identifiers are generated during compilation. The GD identifiers are dis-
played in Table 1 as the result of compilation.
GD identifiers
GD 1.1.1
GD 1.2.1
Setting the
Click the View / Reduction ratio menu. Table 1 below appears with the SR pa-
reduction ratio
rameters.
GD identifiers
SR 1.1
GD 1.1.1
SR 1.2
GD 1.2.1
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
For bhg//CPU1::
mb0 : 20
is the receive area and
mb20 : 6
is the entry for the transmit area.
(mb0 : 20
means that 20 bytes are received starting at mb0 and
mb20 : 6
means that 6 bytes are transmitted starting at mb20.)
marked with "»".
table 1
as314//CPU1::
»
mb0:20
mb20:6
table 1
as314//CPU1::
»
mb0:20
mb20:6
table 1
as314//CPU1::
8
»
mb0:20
8
mb20:6
3 Settings, MPI / OPI
bhg//CPU1::
mb0:20
»
mb20:6
bhg//CPU1::
mb0:20
»
mb20:6
bhg//CPU1::
8
mb0:20
8
»
mb20:6
3
3-49