Siemens SINUMERIK FM-NC Installation And Startup Manual page 93

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

05.97
03.96
Display criteria
If the user's access rights (password) are insufficient, the machine data is not
displayed. If the access rights are fulfilled, the system checks to see if the mask-
ing filters are activated.
Note
You can see to which group a machine data belongs from the machine data
list.
Table 6-4
Masking filter active
Expert mode
Group filter
All others
Index from to
Activating the
The checkboxes are selected with the cursor keys and activated and deacti-
vated with the toggle key.
group filter via
checkboxes
S
S
Note
If the "Index from to" filter is active, please note the following:
If the "first" index (0) only is to be displayed, the settings for the override switch,
for example, (MD 12000.1: OVR FACTOR_AX_SPEED) are not visible.
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
6 Assigning Parameters to the Control and the PLC Program
6.4
Machine data masking filter (SW 4.2 and higher)
Display criteria
S
Inactive: All machine data are displayed
S
Active: Checking the group filter
S
Inactive: The MD is assigned to expert mode
=> MD not displayed
S
Active: The MD is assigned to expert mode
=> MD displayed (note index)
S
Inactive: The MD is assigned to the group
=> MD not displayed
S
Active: The MD is assigned to the group
=> MD displayed (note index)
S
Inactive: For MDs not assigned to a group
=> MD not displayed
S
Active: For MDs not assigned to a group
=> MD displayed (note index)
S
Inactive: All subparameters of the MD are
displayed
S
Active: Only the specified subparameters of the MD are
displayed
If a filter is deactivated (not crossed), the corresponding
machine data are not displayed.
If a filter is activated (crossed), the corresponding machine data are dis-
played. Please also note the "Index from to" filter.