11 Data Backup
11.3 Data backup via MMC 102/103
Set the data
selection
Create the
.
archive file
11-264
Press the vertical softkey MMC data selection. In this display, you define which
directories are to be included in the series start-up file.
When you have selected the data, press the OK softkey. The display changes
and you can now press the Archive softkey to create the archive file
MMCNCPLC.ARC. When the "task finished" message appears, the file
MMCNCPLC.ARC in the archive directory can be output via V.24. The V.24
output should be set to PC format.
You can also create separate series start-up files for the MMC, PLC and NC
areas and output them separately. In this case, the file name is:
MMC:
MMC.ARC
NC:
NC.ARC
PLC:
PLC.ARC
Note
The EEC, QEC and CEC compensation data are not included in the series
start-up file. Reason: Each machine has its own compensation data.