Siemens SINUMERIK FM-NC Installation And Startup Manual page 269

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

12.98
03.96
2. Select menu "7: Backup/Restore"
3. Enter password
4. Select menu "1 Hard disk Backup/restore with ghost"
5. < only if default not suitable >
6. Saving a hard disk
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
11.4 Back up hard disk via Norton GhostR (SW 4.4 and higher)
set parameters for Norton Ghost program:
– < 1 > configure ghost parameters:
If you want to change the default directory path or the type of interface,
select menu 1:
* Set Connection Mode :
<1> PARALLEL (default)
<2> LOCAL
choose the desired setting and confirm.
* Change path:
<3> Change backup image filename (set up directory
for backup file on programming device
e.g. C:\SINUBACK\MMC103\)
<4> Change restore image filename (set up complete path name
for restore file "MMC.GHO" on MMC,
e.g. D:\SINUBACK\MMC103\MMC.GHO)
choose the appropriate setting, enter the path and confirm.
– Enter Yes in response to "Save GHOST parameters?" query save
GHOST parameters? answer "Yes".
<5> Back to previous menu
Return to main menu
– < 2 > Harddisk backup to <pathname>, mode PARALLEL
* When you select this menu, a message window appears:
You are prompted to check whether the connection
between MMC and PG/PC has been established.
The destination path for the MMC image directory is displayed.
This is the image directory to be backed up.
* PG/PC:
In a DOS window or at DOS level, start
the Ghost program with
the command ghost -lps.
11 Data Backup
11-269