System Settings For Power Up, Reset And Part Program Start - Siemens SINUMERIK FM-NC Installation And Startup Manual

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

03.96
6.12
System settings for power up, RESET and part program
start
Concept
The behavior of the control after
S
S
S
can be changed with the machine data
MD 20110: RESET_MODE_MASK (definition of the control initial setting
MD 20112: START_MODE_MASK (definition of the control initial setting
Table 6-25
Power up (POWER ON)
RESET/part program end
Part program start
Procedure
Select the required system behavior.
S
Fig. 6-45
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
6 Assigning Parameters to the Control and the PLC Program

6.12 System settings for power up, RESET and part program start

Power up (POWER ON),
Reset/part program end
Part program start
after power up and reset) and
after part program start).
Change system setting with MD
State
RESET_MODE_MASK
RESET_MODE_MASK
START_MODE_MASK and
RESET_MODE_MASK
After power up (POWER ON)
MD 20110: RESET_MODE_MASK, bit 0 =
Power up
(POWER ON)
bit 0=0
MD 20110
RESET_MODE_MASK
bit 0
bit 0=1
– G codes acc. to MD 20150: GCODE_RESET_VALUES
– Tool length compensation active to MD 20120: TOOL_RESET_
VALUE, MD 20121: TOOL_PRESEL_RESET_V ALUE and
MD 20130: CUTTING_EDGE_RESET_VALUE
– Transformation active to MD 20140: TRAFO_RESET_VALUE
– No coupled-axis groupings active
– No tangential correction active
– Not project. synchronous spindle coupling is deactivated
System settings after power-up
Variable with MD
0 or 1
– G codes acc. to MD 20150: GCODE_
RESET_VALUES
– Tool length compensation not active
– Transformation not active
– No coupled-axis groupings active
– No tangential correction active
– not project. Synchronous spindle
coupling is deactivated
6
6-177

Advertisement

Table of Contents
loading

Table of Contents