03.96
Erasure of SRAM
The following machine data cause a reconfiguration of the control SRAM when
their contents are changed. When a change is made, the alarm "4400 MD
through MD
alteration will cause reorganization of buffer (data loss!)" is displayed. When this
change
alarm is output, all data must be saved because all buffered user data will be
erased during the next booting.
Table 6-8
Machine data for memory configuration
MD number
MD 18020
MM_NUM_GUD_NAMES_NCK
MD 18030
MM_NUM_GUD_NAMES_CHAN
MD 18080
MM_TOOL_MANAGEMENT_MASK
MD 18082
MM_NUM_TOOL
MD 18084
MM_NUM_MAGAZINE
MD 18086
MM_NUM_MAGAZINE_LOCA TION
MD 18090
MM_NUM_CC_MAGAZINE_P ARAM
MD 18092
MM_NUM_CC_MAGLOC_P ARAM
MD 18094
MM_NUM_CC_TDA_P ARAM
MD 18096
MM_NUM_CC_TOA_PARAM
MD 18098
MM_NUM_CC_MON_P ARAM
MD 18100
MM_NUM_CUTTING_EDGES_IN_T OA
MD 18110
MM_NUM_TOA_MODULES
MD 18118
MM_NUM_GUD_MODULES
MD 18120
MM_NUM_GUD_NAMES_NCK
MD 18130
MM_NUM_GUD_NAMES_CHAN
MD 18140
MM_NUM_GUD_NAMES_AXIS
MD 18150
MM_GUD_VALUES_MEM
MD 18160
MM_NUM_USER_MACROS
MD 18190
MM_NUM_PROTECT_AREA_NCKC
MD 18230
MM_USER_MEM_BUFFERED
MD 18270
MM_NUM_SUBDIR_PER_DIR
MD 18280
MM_NUM_FILES_PER_DIR
MD 18290
MM_FILE_HASH_T ABLE_SIZE
MD 18300
MM_DIR_HASH_TABLE_SIZE
MD 18310
MM_NUM_DIR_IN_FILESYSTEM
MD 18320
MM_NUM_FILES_IN_FILESYSTEM
MD 18330
MM_CHAR_LENGTH_OF_BLOCK
MD 18350
MM_USER_FILE_MEM_MINIMUM
MD 28050
MM_NUM_R_PARAM
MD 28080
MM_NUM_USER_FRAMES
MD 28085
MM_LINK_TOA_UNIT
MD 28200
MM_NUM_PROTECT_AREA_CHAN
MD 38000
MM_ENC_COMP_MAX_POINTS [n]
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
6 Assigning Parameters to the Control and the PLC Program
MD name
Number of global user variables
Number of global user variables
Memory tool management
Number of tools
Number of magazines
Number of magazine locations
Number of magazine data
Number of magazine location data
Number of tool-specific data
Number of TOA data
Number of monitoring data
Tool offsets per TOA module
Number of TOA modules
Number of GUD files
Number of global user variables
Number of channel-specific user variables
Number of axis-specific user variables
Memory location for user variables
Number of MACROS
Number of protection areas
User memory in SRAM
Number of subdirectories
Number of files
Hash table size for files in a directory
Hash table size for subdirectories
Number of directories in passive file system
Number of files in passive file system
Max. length of an NC block
Minimum user memory in SRAM
Number of channel-specific R parameters
Number of settable frames
Allocation of a TO unit to a channel
Number of files for protection areas
Number of interpol. points with interpol. compensation