03.96
Example:
S
S
Note
In the case of 1FK6 motors with optical encoders, the torque utilization option is
supported by automatic identification procedures. In this case, traversing mo-
tions < 5 degrees mechanical are not exceeded. The identification procedure
is performed on every power-up.
Non-Siemens
If you are using a non-Siemens motor, you must open the menu for entering the
non-Siemens motor data with the Non-Siemens motor softkey. After you have
motor
entered the data and returned to the motor selection menu, the entry "Non-Sie-
mens motor" is automatically displayed in the selection box for motor 1 or mo-
tor 2.
References:
Once you have selected a motor, the drive data block must be saved individu-
ally for each axis/spindle with the "Save boot file" command. The data block is
stored as a VSAxx.BOT or HSAxx.BOT file in the user memory (SRAM) on the
NC module.
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
6 Assigning Parameters to the Control and the PLC Program
Incremental motor encoder (ERN1387)
1FV6VVV–VVVV–VAVV
Incremental with zero mark: You can now accept the display with "OK"
because the system will correctly preset the other parameters for standard
motors.
Absolute motor encoder (EQN1325)
1FV6VVV–VVVV–VEVV
EnDat interface: You can now accept the display with "OK" because the sys-
tem will correctly preset the other parameters for standard motors.
/FBA/ DM1, Motor, Power Section Parameters
6.9
Axes and spindles
6-117