9 Axis and Spindle Dry Run
9.3

Testing the spindle

9.3
Testing the spindle
Enable spindle
(controller enable NC,
enable on drive)
Define speed
Does the
spindle ro-
tate?
yes
Rota-
tional di-
rection
OK?
yes
Specified speed 100 rpm
Actual
speed
=
setpoint
speed?
yes
1
9-200
Check enabling signals on drive
I/RF module
Drive module
Check interface signals (DB31– 48)
DBB0
DBX1.7
DBX1.5/DBX1.6
DBX1.3
DBX2.1
DBX16.7
DBX3.6
DBX4.3
DBX20.1
DBX2.2
DBX21.7
Check machine and setting data
no
MD 35100–35150
MD 36200
SD 41200
SD 43220
SD 43210
Service display
no
Change MD 32100 AX_MOTION_DIR
no
Check MD 31000 – 31080 (encoder matching)
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
63 pulse enable
64 drive enable
48 DC link start
663 pulse enable
Spindle speed override
Compensation active
Position measuring system 1/2
Axis/spindle disable
Controller enable
Delete S value
Velocity/spindle speed limi-
tation and MD 35160
Feed stop/spindle stop
RFG IS
Spindle reset when MD 35050=1
Pulse enable
Spindle speed limitation
AX_VELO_LIMIT
JOG_SPIND_SET_VELO
SPIND_MAX_VELO_G26
SPIND_MIN_VELO_G25