Drive Optimization - Siemens SINUMERIK FM-NC Installation And Startup Manual

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

6 Assigning Parameters to the Control and the PLC Program
6.9
Axes and spindles
6.9.7
Overview of drive optimization parameters
Table 6-14
Speed controller settings
No.
Identifier
1401
MOTOR_MAX_SPEED[0...7]
1001
SPEEDCTRL_CYCLE_TIME[DRx]
1407
SPEEDCTRL_GAIN_1[0...7,DRx]
1409
SPEEDCTRL_INTEGRATOR_TIME_1[0...7,DRx]
1413
SPEEDCTRL_ADAPT_ENABLE[DRx]
1408
SPEEDCTRL_GAIN_2[0...7,DRx]
1410
SPEEDCTRL_INTEGRATOR_TIME_2[0...7,DRx]
1411
SPEEDCTRL_ADAPT_SPEED_1[DRx]
1412
SPEEDCTRL_ADAPT_SPEED_2[DRx]
1421
SPEEDCTRL_INTEGRATOR_FEEDBK
[0...7,DRx]
Table 6-15
Field weakening with MSD
No.
Identifier
1142
FIELD_WEAKENING_SPEED[DRx]
1143
LH_CURVE_UPPER_SPEED[DRx]
1144
LH_CURVE_GAIN[DRx]
Table 6-16
Current setpoint filter
No.
Identifier
1200
NUM_CURRENT_FILTERS[0...7,DRx]
1201
CURRENT_FILTER_CONFIG[0...7,DRx]
1202
CURRENT_FILTER_1_FREQUENCY[0...7,DRx]
1203
CURRENT_FILTER_1_DAMPING[0...7,DRx]
1204
CURRENT_FILTER_2_FREQUENCY[0,..7,DRx]
1205
CURRENT_FILTER_2_DAMPING[0...7,DRx]
1206
CURRENT_FILTER_3_FREQUENCY[0...7,DRx]
1207
CURRENT_FILTER_3_DAMPING[0...7,DRx]
1208
CURRENT_FILTER_4_FREQUENCY[0...7,DRx]
1209
CURRENT_FILTER_4_DAMPING[0...7,DRx]
1210
CURRENT_FILTER_1_SUPPR_FREQ[0...7,DRx]
1211
CURRENT_FILTER_1_BANDWIDTH[0...7,DRx]
1212
CURRENT_FILTER_1_BW_NUM[0...7,DRx]
1213
CURRENT_FILTER_2_SUPPR_FREQ[0...7,DRx]
1214
CURRENT_FILTER_2_BANDWIDTH[0...7,DRx]
1215
CURRENT_FILTER_2_BW_NUM[0...7,DRx]
1216
CURRENT_FILTER_3_SUPPR_FREQ[0...7,DRx]
1217
CURRENT_FILTER_3_BANDWIDTH[0...7,DRx]
1218
CURRENT_FILTER_3_BW_NUM[0...7,DRx]
1219
CURRENT_FILTER_4_SUPPR_FREQ[0...7,DRx]
1220
CURRENT_FILTER_4_BANDWIDTH[0...7,DRx]
1221
CURRENT_FILTER_4_BW_NUM[0...7,DRx]
6-124
Use the following parameters to optimize the drive (see also Section 10):
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
Name
Setpoint scaling
Speed controller clock cycle
Speed controller P gain
Speed controller reset time
Selection of speed controller adaptation
P gain, upper adaptation speed
Reset time, upper adaptation speed
Lower adaptation speed
Upper adaptation speed
Time constant integrator feedback
Name
Threshold speed field weakening
Upper speed Lh characteristic
Gain factor Lh characteristic
Name
No. of current setpoint filters
current setpoint filter type
Natural freq. setp. current filter 1
Damping current setpoint filter 1
Natural freq. setp. current filter 2
Damping current setpoint filter 2
Natural freq. setp. current filter 3
Damping current setpoint filter 3
Natural freq. setp. current filter 4
Damping current setpoint filter 4
Blocking freq. current setpoint filter 1
Bandwidth current setpoint filter 1
Numerat. bandwidth current setpoint filter 1 FDD/MSD
Blocking freq. current setpoint filter 2
Bandwidth current setpoint filter 2
Numerat. bandwidth current setpoint filter 2 FDD/MSD
Blocking freq. setp. current filter 3
Bandwidth current setpoint filter 3
Numerat. bandwidth current setpoint filter 3 FDD/MSD
Blocking freq. current setpoint filter 4
Bandwidth current setpoint filter 4
Numerat. bandwidth current setpoint filter 4 FDD/MSD
 Siemens AG 2000 All Rights Reserved
03.96
Drive
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
Drive
MSD
MSD
MSD
Drive
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD
FDD/MSD