3 Settings, MPI / OPI
3.6

Machine control panel (MCP)

3.6
Machine control panel (MCP)
Interfaces,
switches and
display elements
Interfaces
LEDs 1...4
Display software
version of MCP
Example
3-66
The following interfaces, switches and display elements are located on the rear
of the machine control panel:
Connection for equipotential bonding conductor
X20
X10
Power supply interface
1
2
3
SHIELD
M24
P24
Fig. 3-11
Position of interfaces on rear panel of MCP
The interfaces (e.g. pin assignment) are described in detail in
References:
/BH/, Operator Components Manual
Table 3-7
Meaning of LEDs 1...4 on rear panel of MCP
Designation
LEDs 1 and 2
Reserved
LED 3
POWER: Lights up when voltage (24 V) is present
LED 4
SEND:
If the "feed start" and "feed stop" keys are pressed while the MCP is powering
up, the software version is displayed in the left-hand, center and right-hand LED
blocks.
The module must have firmware version V 03_01_01 or higher.
After the software version display has been activated, 3/1/1 LEDs light up in the
left-hand/center/right-hand LED blocks.
––> SW version v03_01_01 is installed.
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
1 2 3 4
ON
"
Operator panel
Switch S3
interface (MPI)
Meaning
Changes state after transmission of data
 Siemens AG 2000 All Rights Reserved
08.97
03.96
LEDs 1...4
3
1
S3
4
2
Emergency
STOP button