11 Data Backup
11.2 Data backup via MMC 100
Series start-up
(data backup)
Area-specific
archiving
11-250
Recommendation
MD 11210 UPLOAD_MD_CHANGES_ONLY or the appropriate bits should be
set to "1". With this setting, the transferred files contain only those data which
deviate from the default. This is of advantage with respect to future software
upgrades.
Continue with "Series start-up" or "Area-specific archiving".
5. MMC interface configuration (see above, tape format deselected)
6. Start PCIN data transmission program ("Data In") on PC/PG.
7. When you select "Start-up data" on the MMC (MMC operating area "Ser-
vices", data output "Data out") after pressing the key Input areas NCK and
PLC are offered to you for selection.
8. First select NCK ("NCK" is offered as the name of the archive file) and then
start reading out (softkey Start). Follow exactly the same procedure for the
"PLC" data set.
5. MMC interface configuration (see above, select tape format for all data ex-
cept for drive data).
6. Start PCIN data transmission program ("Data In") on PC/PG, specify file
name.
7. Select data area to be output on MMC (MMC "Services" operating area, data
output "Data Out").
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition