Standard Configuration Of The Hpu (Without Mcp) - Siemens SINUMERIK FM-NC Installation And Startup Manual

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

3 Settings, MPI / OPI
3.5
Handheld programming unit
Signals not
supported
3.5.2

Standard configuration of the HPU (without MCP)

Parameterizing the
+
PLC basic
program FB1
3-58
Machine data that specify the coding of compensation values must be set as
follows:
S
MD 12000: OVR_AX_IS_GRAY_CODE = 1
S
MD 12020: OVR_FEED_IS_GRAY_CODE = 1
S
MD 12040: OVR_RAPID_IS_GRAY_CODE = 1
S
MD 12060: OVR_SPIND_IS_GRAY_CODE = 1
By default, the following signals are not influenced by the MCP emulation, they
are initialized when the control is started up:
S
Keyswitch to position 0
S
Spindle speed override to 0
S
Rapid traverse overlay to 0
Only "BAGNo" and "ChanNo" parameters are provided for FC 26. For this rea-
son, the user needs to determine the information that is otherwise transferred to
the caller via parameters "FeedHold" and "SpindleHold".
The standard configuration comprises a SINUMERIK 840D with
MMC100/102/103 and an HPU.
The parameter assignment at FB1 for the HHP operating components corre-
spond to those of the 1st MCP:
MCPNum:=1
MCPIn:=P#I0.0
MCPOut:=P#Q0.0
MCPStatRec:=P#Q12.0
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
(one HPU)
(HPU input signals)
(HPU output signals)
(status double word)
 Siemens AG 2000 All Rights Reserved
12.97
08.97
03.96

Advertisement

Table of Contents
loading

Table of Contents