3 Settings, MPI / OPI
3.5
Handheld programming unit
Activate status
SDB
HPU address
3-64
Click the View / Status softkeys in the menu.
The following table 1 appears:
GD identifiers
as314/CPU1::
GST
GDS 1.1
SR 1.1
4
GD 1.1.1
»
qb0:8
GDS 1.2
SR 1.2
1
GD 1.2.1
ib0:8
GDS 2.1
SR 2.1
4
GD 2.1.1
»
qb16:8
GDS 2.2
SR 2.2
1
GD 2.2.1
ib16:8
Now enter the status double words for GDS1.2 and GDS 2.1.
Extract from table 1:
GD identifiers
as314/CPU1::
GDS 1.2
ad12
GDS 2.2
ad24
Once you have entered the status, you must compile your configuration again.
The SDB has been generated during compilation. Now transfer the SDB for
CPU program as314 to the PLC CPU. (PLC must be in the STOP state).
Procedure:
1. Click on File/Download to PLC menu
2. Download window appears. Select as314//CPU1:: and confirm with OK soft-
key.
3. Switch PLC into RUN mode (restart).
The default setting for the MCP is 6 and the MPI address for the HPU is 14. The
address is set in FB1 for each device.
The default addresses are:
MCP:
6
HPU:
11