Plural Character Type Variable (S) Reading / Writing Command - YASKAWA DX100 Instructions Manual

Options; for high-speed ethernet server function
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

DX100

3.3.33 Plural Character Type Variable (S) Reading / Writing Command

Command No. 0x306
Instance
Specify one out of followings
0 to 99 (for standard setting)
Attribute
Fixed to "0"
Service
0x33 : Read plural data
0x34 : Write plural data
32bit integer
Byte 0
1
Number
2
S variable 1
3
4
5
:
114
S variable 29
115
116
117
Status
Respond by one in the followings
0x00 : respond normally
Other than 0x00
Added status size
0: no added status
1: 1 WORD
2: 2 WORD
Added status
The error code specified by the
added status size
3
Transmission Procedure
3.3 Respective Commands for Robot Control
Request
Sub header part
<Details>
Specify the variable number (the first number with which
reading/writing is executed)
Follow the numbers of the variable specified by the
parameter since the extended variable is an optional
function.
Specify "0"
Only batch access of all elements is valid
Specify the accessing method to the data.
0x33: Read plural data
0x34: Write plural data
Data part
Byte 1
Byte 2
Byte3
Answer
Sub header part
<Details>
: respond abnormally
"1" indicates 1 WORD of added status data, and "2"
indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status
code is "1" and that of 2 WORD exists if the code is "2".
3-67
<Details>
Maximum: 29
Variable data part is valid only when writing.
Only the number of data is valid when
reading.
HW1480958
162529-1CD
86 of 119

Hide quick links:

Advertisement

Table of Contents
loading