4.5 Wiring the MSS
Step
Action
5
Connect the light curtain to the central unit
of the MSS (terminal IN1/IN2) with
Output 1 of the light curtain: Terminal
IN1
Output 2 of the light curtain: Terminal
IN2
Note:
Please refer here to the operating
instructions for the light curtain.
6
Connect the two-hand operator panel to
the central unit of the MSS with:
NC pushbutton 1: Terminal T2/IN6
NO pushbutton 1: Terminal T1/IN5
NC pushbutton 2: Terminal T2/IN8
NO pushbutton 2: Terminal T1/IN7
7
Connect the Start pushbutton on the
expansion module 2/4 F-DI 2F-DO of the
MSS with:
NO contact: Terminal T1/IN1
32
Result