Enabling Button - Siemens Sirius 3RK3 System Manual

Modular safety system industrial switchgear monitoring and control devices
Hide thumbs Also See for Sirius 3RK3:
Table of Contents

Advertisement

Description of the software
6.7 Functions
See also
Messages for protective door (Page 265)
6.7.3.6

Enabling button

Description
With the function "Enabling button", the signals from the enabling buttons are evaluated by
means of an NO contact.
An enabling button is always monitored for cross-circuit.
When the enabling button is actuated, the function output Q is activated, i.e. set to "1".
Parameters
Parameter name
General
Parameter - Input
174
Name
Element number
Element activated
Function output substitute
value
Type
IN1
IN2
Description/parameter value
You can enter a name for the element here.
Consecutive number which is automatically assigned. You can
change the number.
When this parameter is active, the function is processed in the
safety logic.
When the parameter is deactivated, the set substitute value is
made available at the output Q.
"0" or "1" can be assigned to the substitute value when the
element is deactivated.
Substitute value "0" means output Q = 0
substitute value "1" means output Q = 1
Use these parameters to determine the input type of the function:
Single-channel (NO)
IN1 is monitored for "1", i.e. the function output Q is
deactivated when there is a "0" signal.
Two-channel (NONO)
IN1 and IN2 are monitored for "1", i.e. the function output Q is
deactivated when there is at least one "0" signal.
Select the input to be processed by the function.
Only available with the parameter - Input > Two-channel type
(NONO):
IN2 is automatically assigned depending on the selected input IN1.
Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02