Siemens Sirius 3RK3 System Manual page 231

Modular safety system industrial switchgear monitoring and control devices
Hide thumbs Also See for Sirius 3RK3:
Table of Contents

Advertisement

When you press "MODE" and "SET" at the same time, editing screen 1 with the entry "EXIT"
is selected. "When you press "EXIT", this must then be confirmed by pressing "SET".
If the DP address cannot be changed on a device, the following message is displayed when
you choose "ADR":
Display
ADR•
LOCK•
You can acknowledge this message by choosing "SET" or "MODE". After 30 seconds of
inactivity, the display automatically returns to standard mode.
Display (editing screen 1)
DP••
••126
The 2nd row in the display contains the current DP address (0 ... 126; right-justified). If an
address has not yet been set, the default address 126 is displayed.
When you choose "MODE", the hundreds are incremented (sequence: 0, 1, 0, etc.).
When you choose "SET", this digit is confirmed and the system switches to the tens. When
you double-click "SET", you can go back one digit (i.e. from the hundreds to the ones). The
address is not applied when you do this.
Display (editing screen 2)
DP••
••X26
When you press "MODE", the tens are incremented (sequence: 0, 1, 2, to 9); double-clicking
"MODE" counts back one digit.
When you choose "SET", this digit is confirmed and the system switches to the next digit.
When you double-click "SET", you can go back one digit (i.e. from the tens to the hundreds).
Display (editing screen 3)
DP••
••XX6
When you press "MODE", the ones are incremented (sequence: 0, 1, 2, to 9); double-
clicking "MODE" counts back one digit.
When you press "SET", this digit is applied and the set PROFIBUS address (indicated here
by "•XXX") is displayed. When you double-click "SET", the system goes back one digit (i.e.
from the ones to the tens).
Display
•XXX
OK•••
The message above indicates that the PROFIBUS address was successfully saved. You can
acknowledge this message by choosing "SET" or "MODE". The display then returns to
standard mode.
Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02
7.5 Integrating the Modular Safety System 3RK3 in DP master systems
1. row: not flashing
2nd row: flashing
1. row: not flashing
2nd row: 1. digit in DP address flashing
1. row: not flashing
2nd row: 2. digit in DP address flashing
1. row: not flashing
2nd row: 3. digit in DP address flashing
1. row: not flashing
2nd row: flashing
Operator control