Device
Description
commands
Delete memory
Deletes the data on the memory module
module
of the connected safety relay.
Note:
With this command the connection to the
safety relay is interrupted and the
configuration is closed.
After the memory module has been
deleted a reset (via the RESET button)
or a complete restart of the safety relay
has to be carried out as otherwise an
online connection to the safety relay is
not possible.
Cancel access
Cancels all passwords, i.e. all access
rights
rights are revoked.
6.4.3.11
Diagnostics configuration
Using the "Target system" > "Diagnostics configuration" menu command, activate the
following submenu options:
Module status
● You activate the module status display which is displayed in color in the configuration
table.
● This menu command can only be selected if the main system is activated in the
navigation window.
Device messages
You activate the "Device messages" dialog box.
6.4.3.12
Diagnostics logic
Using the "Target system" > "Diagnostics logic" menu command, activate the following
submenu options:
Monitor
● The "Target system" > "Diagnostics logic" > "Monitor" menu command shows the
statuses of the inputs and outputs, of the functions and of the connections between the
functions according to their status.
● This menu command can only be selected if the following conditions are met:
– A safety relay is opened online.
– The logic diagram with the safety circuit is activated.
Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02
6.4 Description of the menu commands
Can be activated in
Feedback
Configuring
•
Memory module not plugged in
mode
Memory module defective
Programming active
Programming successful
Programming error
Configuring
•
•
mode
Safety mode
•
•
Description of the software
No access rights for controlling
exist.
No access rights for circuit
diagnostics exist.