Getting Started

4.1

Introduction

This section provides a step-by-step guide to commissioning a Modular Safety System 3RK3
(MSS) using an example demonstrating how to protect a metalworking press.
The essential steps for commissioning the MSS are as follows:
1. Installation
2. Wiring
3. Configuring
4. Function test
4.2

Hardware and software requirements

To commission the MSS in this example, you will need the following hardware and software
components:
Number
1
1
1
1
1
1
1
2
1
1
1
To configure the modules, you need a programming device or PC with the operating system
MS Windows 2000 Professional SP3 / SP4, MS Windows XP Professional SP2, or
MS Windows VISTA Business / Ultimate 32 bit.
Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02
Device
3RK3 Basic
Expansion module 2/4 F-DI 2 F-DO
24V PELV power supply unit
Light curtain (ESPE)
Pushbutton (NO contact)
EMERGENCY STOP control device
Two-hand operator panel
Contactors
0.025 m connection cable
PC cable
MSS ES 2008 (software)
Order number
3RK3111-1AA10
3RK3231-1AA10
6ES73071EA00-0AA0
3RG7846-3SB04-0SS0 (transmitter)
3RG7846-3SB04-0SS1 (receiver)
3SB3801-0DD3
3SB3801-0EG3
3SB3863-4BB
3RT1015-1BB42
3UF7930-0AA0-0
3UF7940-0AA00-0, product version 2
3ZS1314-5CC10-0YA5
4
27