Messages During The Consistency Check - Configuration - Siemens Sirius 3RK3 System Manual

Modular safety system industrial switchgear monitoring and control devices
Hide thumbs Also See for Sirius 3RK3:
Table of Contents

Advertisement

Description of the software
6.5 Identification and configuration
In this dialog window, the following parameters are shown:
● In online mode: The parameters of the uploaded module.
● Editable parameters
The parameters are described in the following table:
Parameter name
Configuration
Module
Order No.
Firmware
Equipment identifier
Inputs
Outputs
6.5.2.6

Messages during the consistency check - Configuration

The following HW configuration messages exist:
Message
The expansion modules
must be configured in
succession.
The central unit must be
available.
134
Parameter value
The designation of the selected module is displayed here. The field has a gray
background and cannot be changed by the user.
The order number of the selected module is shown here. The field has a gray
background and cannot be changed by the user.
The firmware of the selected module is shown here. The field has a gray
background and cannot be changed by the user.
Here you can specify a user-defined equipment identifier (max. 32 characters)
for the selected module and assign it to inputs and outputs.
The number of inputs of the selected module is shown here.
The number of outputs of the selected module is shown here.
Type
Message text
Error
"Configuration: There is a gap before
an expansion module."
Error
"Configuration: A central unit always
needs to be configured at slot 3."
Remedy
Correct the configuration "manually",
possibly context menu function
"Delete blank rows automatically".
Drag the central unit from the catalog
window to slot 3 in the configuration
table.
Modular Safety System 3RK3
System Manual, 10/2008, 926 2530-02 DS 02