Download Print this page

Absolute / Dynamic Plausibilty - Mahindra XUV 500 Diagnostic Manual

Hide thumbs Also See for XUV 500:

Advertisement

DIAGNOSTIC MANUAL
P1128 - Coolant Temperature Sensor Absolute Test non plausible error
P1126 - Coolant Temperature Sensor Dynamic Test non plausible error

ABSOLUTE / DYNAMIC PLAUSIBILTY

When the engine is switched ON then the ECU detects the temperature. After that when the engine runs
then the temperature output on a time frame is detected and compared against predetermined slope
COMPONENT LOCATION
NORMAL
OPERATION
DTC DETECTING
CONDITION
PROBABLE
CAUSES
LAMP STATUS
DTC REACTION
HEALING
CONDITION
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
EMS
The coolant temperature rises to a specified temperature within a specific time
period -
absolute test
It also compares the rate of rise with a predefined rate of rise defined during
calibration- dynamic test
The coolant temperature do not rise enough within a specific time period,
The coolant temperature does not reach a warmed-up fuel control
temperature within a specific time
Thermostat removed
Thermostat malfunctioning
No lamp indication
No reaction
Self healing
Thermostat
.
MAN-00152
OCT 2011/Rev 1
.
50

Hide quick links:

Advertisement

loading