DIAGNOSTIC MANUAL
LOW SPEED COOLING FAN
The cooling fan is controlled by EMS ECU . The low speed cooling fan will be ON whenever A/C is
switched ON (middle pressure switch is OFF) or coolant temperature is more than 98°C and less than
101°C
COMPONENT LOCATION
NORMAL
OPERATION
DTC DETECTING
CONDITION
PROBABLE
CAUSES
LAMP STATUS
DTC REACTION
HEALING
CONDITION
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
EMS
P0480 - Low speed fan open load
Depending upon the AC ON status or coolant temperature , the EMS ECU
controls the low speed cooling fan
Electrical fan driver detects open load
Open low speed fan control signal wire
No warning lamp indication
No reaction
Ignition OFF/ON
MAN-00152