DIAGNOSTIC MANUAL
GROUP
ACCELERATOR PEDAL
MODULE
HFM SENSOR-
TEMPERATURE
BOOST PRESSURE
MODULATOR
VEHICLE SPEED
SENSOR
SENSOR SUPPLY
MONITORING
RAIL PRESSURE
GOVERNOR
MAIN RELAY
BRAKE SWITCH
CLUTCH SENSOR
GEAR NEUTRAL
SENSOR
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
EMS
DTC
Signal range check for APP sensor1 above maximum
P2123
limit
Signal range check for APP sensor2 above maximum
P2128
limit
P2138
Plausibility error between APP signal1 and signal2
Signal range check for HFM 7 temperature sensor
P0113
above maximum limit
Signal range check for HFM 7temperature sensor
P0112
below minimum limit
P0045
Boost pressure modulator open load error
P0048
Boost pressure modulator short circuit to battery
P0047
Boost pressure modulator short circuit to ground
P1645
Boost pressure modulator over temperature error
P0501
Vehicle speed sensor plausibility error
P0641
Sensor supply voltage1 monitoring error
P0651
Sensor supply voltage2 monitoring error
P0697
Error Sensor supplies 3
Rail pressure positive governor deviation error in
P1B87
Metering Unit mode
Positive governor deviation and setpoint value of the
P1C87
fuel volume flow through the metering unit.
Rail pressure negative governor deviation error in
P1B88
Metering Unit mode
Rail pressure below minimum limit error in Metering
P1D87
Unit mode
Rail pressure above maximum limit error in Metering
P1C88
Unit mode
P068A
Main relay early opening error
P068B
Main relay struck error
P0504
Brake Signal plausibility error.
P0704
Clutch non plausible error
P1704
Gear Neutral Signal is not plausible