DIAGNOSTIC MANUAL
METERING UNIT
The component driver for the metering unit regulates the opening and closing f the metering unit based
on the rail pressure set point and the actual value
COMPONENT LOCATION
NORMAL
OPERATION
DTC DETECTING
CONDITION
PROBABLE
CAUSES
LAMP STATUS
DTC REACTION
HEALING
CONDITION
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
P0003 - Metering unit output short circuit to ground error
When ignition ON , no malfunction detected by EMS ECU in the metering unit
circuit
Short to ground is detected in metering unit circuit
Short in metering circuit
Faulty metering unit
Faulty EMS ECU
OBD lamp ON
Engine shuts off
Ignition OFF/ON
EMS
MAN-00152
OCT 2011/Rev 1
189