Download Print this page

Mahindra XUV 500 Diagnostic Manual page 298

Hide thumbs Also See for XUV 500:

Advertisement

DIAGNOSTIC MANUAL
COMPONENT LOCATION
NORMAL
OPERATION
DTC DETECTING
CONDITION
PROBABLE
CAUSES
LAMP STATUS
DTC REACTION
HEALING
CONDITION
Note- This DTC's will be viewed in the diagnostic tool in healed condition only
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
EMS
P068A - Main relay early opening error
P068B - Main relay struck error
EMS ECU checks the main relay actuation time during initialization and is within
the range
ECU checks the main relay during operation and no sticky operation noticed
The main relay is not operating in the set time
Open /short wiring harness
Loosen wiring harness connectors
Sticky relay
Faulty BEC
No lamp indication
Engine will not start
No communication from EMS
Ignition OFF/ON
MAN-00152
OCT 2011/Rev 1
297

Hide quick links:

Advertisement

loading