Table Of Contents; Ignition Off; Remove The Fan High Speed - Mahindra XUV 500 Diagnostic Manual

Hide thumbs Also See for XUV 500:

Advertisement

DIAGNOSTIC MANUAL
Ensure the fan high speed relay
is fixed properly in the
Connector of the engine
compartment fuse box

Remove the fan high speed

relay
Check the functioning of relay by
providing 12V to terminal 85
and ground to terminal 86
STEP 3
Remove the fan high speed
relay
pin 30 and pin 86 of the fan
high speed relay
YES
Go to STEP 4
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
Verify if P0694 is present?
YES
Is P0694 present?
YES
Is a clicking sound
heard?
Is the value =∞Ω?
MAN-00152
NO
Intermittent problem exists
Refer the intermittent problem
inspection procedure
NO
Replace the fan high speed relay
with a new one
NO
Replace the fan high speed relay
with a new one