Download Print this page

Mahindra XUV 500 Diagnostic Manual page 22

Hide thumbs Also See for XUV 500:

Advertisement

DIAGNOSTIC MANUAL
GROUP
COOLING FAN RELAY
FUEL TEMPERATURE
SENSOR
IQA CODE
MONITORING
INJECTORS
METERING UNIT
BOOST PRESSURE
SENSOR
BOOST TEMPERATURE
SENSOR
RAIL PRESSURE
SENSOR
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
EMS
DTC
P0480
Low speed fan open load
P0481
High speed fan open load
P0692
Low speed fan short to battery
P0694
High speed fan short to battery
P0691
Low speed fan short to ground
P0693
High speed fan short to ground
Signal range check for fuel temperature sensor above
P0183
maximum limit
Signal range check for fuel temperature sensor below
P0182
minimum limit
P268C
Cylinder1 injector adjustment code incorrect error
P268D
Cylinder2injector adjustment code incorrect error
P268E
Cylinder 3 injector adjustment code incorrect error
P268F
Cylinder4 injector adjustment code incorrect error
P0201
Cylinder1 injector open load error
P0202
Cylinder2 injector open load error
P0203
Cylinder3 injector open load error
P0204
Cylinder4 injector open load error
P0261
High side - Low side short circuit for cylinder1 injector
P0264
High side - Low side short circuit for cylinder2 injector
P0267
High side - Low side short circuit for cylinder3 injector
P0270
High side - Low side short circuit for cylinder4 injector
P2146
Short circuit in bank 0
P0001
Metering unit open load error
P0004
Metering unit output short circuit to battery error
P0003
Metering unit output short circuit to ground error
Signal range check for manifold absolute pressure sensor
P0238
above maximum limit
Signal range check for intake manifold absolute pressure
P0237
sensor below minimum limit
Signal range check for intercooler downstream
P007D
temperature sensor above maximum limit
Signal range check for intercooler downstream
P007C
temperature sensor below minimum limit
Signal range check for rail pressure sensor above
P0193
maximum limit
Signal range check for rail pressure sensor below
P0192
minimum limit
P0191
Rail pressure offset value above maximum limit
P1191
Rail pressure offset value above minimum limit
P169F
Rail pressure raw value is intermittent
MAN-00152
OCT 2011/Rev 1
DESCRIPTION
PAGE
NO
109
112
115
119
123
126
129
133
138
140
142
144
146
150
154
158
162
166
170
174
178
181
185
189
193
198
203
208
212
217
222
225
228
21

Hide quick links:

Advertisement