DIAGNOSTIC MANUAL
P0113 - Signal range check for HFM temperature sensor above maximum limit
HFM TEMPERATURE SENSOR
The HFM temperature sensor is a variable resistor whose resistance changes as the temperature of the air
flowing past the sensor changes.(NTC resistor) When the intake air temperature is low, the sensor
resistance is high; when the intake air temperature is high, the sensor resistance is low.
COMPONENT LOCATION
NORMAL
OPERATION
DTC DETECTING
CONDITION
PROBABLE
CAUSES
LAMP STATUS
DTC REACTION
HEALING
CONDITION
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
EMS
During ignition ON , the measured output voltage value of the intake air
temperature sensor is within the specified range
The measured output voltage of the intake air temperature sensor is more
than the specified range
Open HFM temperature sensor wiring harness
Short to battery of HFM temperature sensor wiring harness
Faulty HFM temperature sensor
Faulty EMS ECU
OBD lamp ON
Engine will run with default air temperature as 20°C
Ignition OFF/ON
MAN-00152
OCT 2011/Rev 1
248