DIAGNOSTIC MANUAL
CONTINOUS TORQUE MONITORING
DTC
P1633
ECU Monitoring: PoI2 qty error
ECU Monitoring:PoI2 shut off error
P1634
ECU Monitoring:PoI3 efficiency factor error
P1635
P1637
ECU Monitoring: Injection quantity correction error
P061B
ECU Monitoring: Torque comparison error
P163E
ECU Monitoring: Torque monitoring level2 error
P1639
ECU Monitoring: Lead torque monitoring level2 error
P163D
ECU Monitoring: Set torque monitoring level2 error
NORMAL
OPERATION
DTC DETECTING
CONDITION
PROBABLE
CAUSES
LAMP STATUS
HEALING
CONDITION
Corrective Action -
1. Using diagnostic tester clear the DTC.
2. Turn ignition OFF/ON
3. Check for the DTC . If the DTC still exists , repeat the steps 1 and 2 for 3 times
4. If DTC still exists replace the EMS ECU with a new one
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution© 2011 Mahindra & Mahindra Ltd.
EMS
The voltage monitoring of the injector energizing time is found OK
If the difference between the programmed energizing time and the measured
energizing time exceeds a limit then this error will be registered
Faulty EMS ECU
No lamp indication
Ignition OFF/ON
Description