Configuring Network Operation; Overview - Siemens SIMATIC HMI TP1000F Mobile RO Operating Instructions Manual

Table of Contents

Advertisement

5.11

Configuring network operation

5.11.1

Overview

Addressing computers
Computers are usually addressed using computer names within a PROFINET network.
However, the network address is set with RemoteOperate.
Determine the following parameters:
● Is DHCP used in the local network for dynamic assignment of addresses?
If not, get a TCP/IP address for the HMI device.
● Which TCP/IP address does the default gateway have?
● If a DNS network is used, what is the address of the name server?
● If a WINS network is used, what is the address of the name server?
Configuration includes:
● Specifying the computer name of the HMI device
● Specifying the IP address and name server
● Specifying the logon data
NOTICE
RemoteOperate connection overwrites network parameters
When you start RemoteOperate and connect the client to a server in the server selection
list, RemoteOperate overwrites the network parameters with the stored properties of the
server connection. If another application needs the network parameters for a network
connection, note the following:
• Note down the network parameters of the application.
• After the start, exit RemoteOperate and re-configure the network.
• Alternatively, select a shared IP address and subnet mask for RemoteOperate and your
Parameterization is described from section "Specifying the computer name of the HMI device
(Page 112)" on.
TP1000F Mobile RO
Operating Instructions, 08/2017, A5E39831415-AA
application.
Parameterizing the Mobile Panel
5.11 Configuring network operation
111