MACHine Subsystem

TYPE

Example
OUTPUT XXX;":MACHINE1:RESOURCE A,C,RANGE1"
Query
:MACHine{1|2}:RESOURCE?
The RESource query returns the current resource terms assigned to the
specified analyzer. If no resource terms are assigned, no <res_id> is returned.
Returned Format
[:MACHine{1|2}:RESOURCE] <res_id>[,<res_id>,...]<NL>
Example
OUTPUT XXX;":MACHINE1:RESOURCE?"
TYPE
Command
:MACHine{1|2}:TYPE <analyzer type>
The TYPE command specifies what type a specified analyzer (machine) will
be. The analyzer types are state or timing. State Compare (COMPare) and
SPA are considered to be state analyzers because they use an external clock,
but need to specified as COMPare or SPA.
The TYPE command also allows you to turn off a particular machine.
Only one timing analyzer can be specified at a time.
<analyzer
{OFF|COMPare|SPA|STATe|TIMing}
type>
Example
OUTPUT XXX;":MACHINE1:TYPE STATE"