Overview:high - HP 16554A Programmer's Manual

State/timing logic analyzers
Table of Contents

Advertisement

OVERView:HIGH

Command
:SPA{1|2}:OVERView:HIGH <high_pattern>
The OVERView:HIGH command sets the upper boundary of the State
Overview measurement. A query returns the current setting of the upper
boundary.
Setting the upper boundary defaults the data accumulators, statistic
counters, and the number of buckets and their size.
<high_pattern>
"{#B{0|1}...|
#Q{0|1|2|3|4|5|6|7}...|
#H{0|1|2|3|4|5|6|7|8|9|A|B|C|D|E|F}.. .|
{0|1|2|3|4|5|6|7|8|9}...}"
Example
OUTPUT XXX;":SPA1:OVERView:HIGH '23394'"
OUTPUT XXX;":SPA2:OVERView:HIGH '#Q4371'"
Query
:SPA{1|2}:OVERView:HIGH?
Returned Format
[:SPA{1|2}:OVERView:HIGH] <high_pattern><NL>
Example
10 DIM String$[100]
20 OUTPUT XXX;":SELECT 1"
30 OUTPUT XXX;":SPA1:OVERView:HIGH?"
40 ENTER XXX;String$
50 PRINT String$
60 END
SPA Subsystem
OVERView:HIGH
16–9

Advertisement

Table of Contents
loading

This manual is also suitable for:

16555d16555a

Table of Contents