Range - HP 16554A Programmer's Manual

State/timing logic analyzers
Table of Contents

Advertisement

Example
OUTPUT XXX;":MACHINE1:SWAVEFORM:MLENGTH 262144"
Query
:MACHine{1|2}:SWAVeform:MLENgth?
The MLENgth query returns the current analyzer memory depth selection.
Returned Format
[:MACHine{1|2}:SWAVeform:MLENgth] <memory_length><NL>
Example
OUTPUT XXX;":MACHINE1:SWAVEFORM:MLENGTH?"

RANGe

Command
MACHine{1|2}:SWAVeform:RANGe <number_of_samples>
The RANGe command allows you to specify the number of samples across
the screen on the State Waveform display. It is equivalent to ten times the
states per division setting (states/Div) on the front panel. A number between
10 and 5000 may be entered.
integer from 10 to 5000
<number_of_
samples>
Example
OUTPUT XXX;":MACHINE2:SWAVEFORM:RANGE 80"
Query
MACHine{1|2}:SWAVeform:RANGe?
The RANGe query returns the current range value.
Returned Format
[MACHine{1|2}:SWAVeform:RANGe] <number_of_samples><NL>
Example
OUTPUT XXX;":MACHINE2:SWAVEFORM:RANGE?"
SWAVeform Subsystem
RANGe
8–9