Range - HP 16554A Programmer's Manual

State/timing logic analyzers
Table of Contents

Advertisement

COMPare Subsystem

RANGe

RANGe
Command
:MACHine{1|2}:COMPare:RANGe {FULL |
PARTial,<start_line>,<stop_line>}
The RANGe command allows you to define the boundaries for the
comparison. The range entered must be a subset of the lines in the
acquisition memory.
integer from –122880 to +122880 (HP 16554A) or –253951 to +253951
<start_line>
(HP 16555A) or –507904 to +507904 (HP 16555D)
integer from
<stop_line>
(HP 16555A) or +507904 (HP 16555D)
Example
OUTPUT XXX;":MACHINE1:COMPARE:RANGE PARTIAL, –511, 512"
OUTPUT XXX;":MACHINE2:COMPARE:RANGE FULL"
Query
:MACHine{1|2}:COMPare:RANGe?
The RANGe query returns the current boundaries for the comparison.
Returned Format
[:MACHine{1|2}:COMPare:RANGe] {FULL|PARTial,<start_line>,
<stop_line>}<NL>
Example
10 DIM String$[100]
20 OUTPUT 707;":SELECT 2"
30 OUTPUT 707;":MACHINE1:COMPARE:RANGE?"
40 ENTER 707;String$
50 PRINT "RANGE IS ";String$
60 END
10–10