Schart; Accumulate - HP 16554A Programmer's Manual

State/timing logic analyzers
Table of Contents

Advertisement

SCHart Subsystem

SCHart

SCHart
Selector
:MACHine{1|2}:SCHart
The SCHart selector is used as part of a compound header to access the
settings found in the State Chart menu. It always follows the MACHine
selector because it selects a branch below the MACHine level in the
command tree.
Example
OUTPUT XXX;":MACHINE1:SCHART:VAXIS 'A', '0', '9'"

ACCumulate

Command
MACHine{1|2}:SCHart:ACCumulate {{ON|1} | {OFF|0}}
The ACCumulate command controls whether the chart display gets erased
between each individual run or whether subsequent waveforms are displayed
over the previous waveforms.
Example
OUTPUT XXX;":MACHINE1:SCHART:ACCUMULATE OFF"
Query
MACHine{1|2}:SCHart:ACCumulate?
The ACCumulate query returns the current setting. The query always shows
the setting as the character "0" (off) or "1" (on).
Returned Format
[:MACHine{1|2}:SCHart:ACCumulate] {0|1}<NL>
Example
OUTPUT XXX;":MACHINE1:SCHART:ACCUMULATE?"
9–4