OVERView:MLENgth

OVERView:MLENgth
Command
:SPA{1|2}:OVERView:MLENgth <memory_length>
The MLENgth command specifies the memory depth. Valid memory depths
range from 4096 states (or samples) through the maximum system memory
depth minus 8192 states (HP 16554A/HP 16555A) or minus 16384 states
(HP 16555D). Memory depth is affected by acquisition mode. If the
<memory_depth>
closest legal setting will be used.
<memory_length>
{4096 | 8192 | 16384 | 32768 | 65536 | 131072 | 262144
| 516096 (HP 16554A)
| 524288 | 1040384 (HP 16555A)
| 524288 | 1048576 | 2080768 (HP 16555D)}
Example
OUTPUT XXX;":SPA1:OVERVIEW:MLENGTH 262144"
Query
:SPA{1|2}:OVERView:MLENgth?
The MLENgth query returns the current analyzer memory depth selection.
Returned Format
[:SPA{1|2}:OVERView:MLENgth] <memory_length><NL>