Type - HP 16500C Programmer's Manual

Logic analysis system
Hide thumbs Also See for 16500C:
Table of Contents

Advertisement

TGTctrl Subsystem

TYPe

TYPe
Command
:TGTctrl:TYPe<N> {{TOGgle|0} | {PULse|1} |
{SEQuence|2}}
The TYPe command sets the signal type for the specified signal. It does not
turn on the signal.
An integer, 0 through 7, specifying signal.
<N>
Example
OUTPUT XXX;":TGT:TYP2 SEQ"
Query
:TGTctrl:TYPe<N>?
The TYPe query returns the current type of the signal. The default type is
toggle.
Returned Format
[:TGTctrl:TYPe<N>] <type><NL>
<type>
{0|1|2}
sequence.
14–16
where 0 indicates toggle, 1 indicates pulse, and 2 indicates

Hide quick links: